O-O TAA uncertainties

Scope: PWG
PWG-MM (Monte Carlo generators and Minimum Bias)
Energy
none
System
none
Figure Image
Figure image (.eps)
Figure image (.pdf)
Figure Caption

These uncertainties have been obtained by: 

  • Considering the O 3pF variations from H. De Vries, C. W. De Jager, and C. De Vries, Atom. Data Nucl. Data Tabl. 36, 495 (1987).
  • Considering a variation of the sigmaINEL at 6.37TeV (69-70-71 mb) 
  • Considering a 1% anchor point variation at 80% of the hadronic cross-section 

Note: they are meant for illustration purposes, as real data may contain effects that are not foreseen in this idealized calculation.